News|Articles|November 23, 2026

CGM Discharge Barriers Center on Prior Authorization and Education

Fact checked by: Ashley Gallagher, MA
Listen
0:00 / 0:00

Key Takeaways

  • Prior authorization staffing gaps and DME timelines routinely interrupt post-discharge CGM access; pharmacy-benefit fulfillment can be faster, creating inconsistent pathways across payers and sites.
  • Pre-discharge CGM placement with rapid 3–5 day follow-up, educator-led supply coordination, and streamlined calibration/flowsheet policies can improve continuity without waiting for payer reform.
SHOW MORE

Faculty say insurance hurdles and supply delays derail continuous glucose monitor use after discharge and share low-cost fixes health systems use.

Prior authorization, durable medical equipment (DME) supply chains, and patient education emerged as the main obstacles to keeping patients on continuous glucose monitors (CGMs) after a hospital stay, according to faculty at an October

Population Health Roundtable in North Carolina. Clinicians from Novant Health, Duke, the University of North Carolina (UNC), and WakeMed also described low-cost workflow fixes that do not wait on payer reform.

Why Do CGM Discharge Plans Break Down?

The American Diabetes Association’s Standards of Care call for CGM access from diagnosis for people on insulin, regardless of hemoglobin A1C or payer. Faculty in attendance said operations, not clinical evidence, keep that from happening at discharge.

Prior authorization was the most common point of contention. Inpatient teams generally are not staffed to complete prior authorizations, and endocrinologists cannot see every patient admitted with new-onset diabetes. “I think insurance is just so huge with this. It’s the crux of, I think, what a lot of us have to struggle with and why there’s so many workflow issues with this,” said Holly Canupp, PharmD, BCACP, CPP, CDE, of Duke University Hospital. Other faculty added that DME-supplied CGMs rarely reach patients within 10 to 14 days of discharge, while pharmacy-benefit devices sometimes do.

A few organizations have found workarounds. At WakeMed, a pediatric inpatient quality nurse supervisor launched a pilot to place a CGM on every new-onset patient before discharge. Families are then seen within 3 to 5 days, when diabetes educators arrange supplies and staff handle prior authorizations. WakeMed also persuaded its hospital to let pediatric nurses use CGM values to mealtime dosing instead of finger sticks, with a dedicated flowsheet row. Adults lack that exception at WakeMed, where the pathology department has declined to allow CGM readings to be entered as laboratory results. UNC is developing a policy to require calibration once daily rather than before every meal.

Novant Health’s multidisciplinary diabetes governance group supports discharge with clinical CGMs for 2 weeks, paired with a defined transition-of-care visit. “I really believe strongly [that] for it to be successful, you need that multidisciplinary group pushing it forward rather than just relying on the endocrinology service to be the ones that own that,” said Mackie King, PharmD, MBA, BCPS, AAHIVP, CPP, of Novant Health.

Making CGM Data Usable

Faculty said patients most often abandon CGMs because sensors fall off or alarms overwhelm them, so they urged building troubleshooting into discharge education. One inexpensive fix in the adhesive overpatch.

“From summers at diabetes camp, I can say, truly a $0.25 overpatch, you could have them on the floors and pop it on before they leave,” said Emelia “Mia” Zhu, MPH, RD, LDN, CDCES, of Duke Primary Care. She also noted that hospital supply channels do not usually stock them. Faculty also advised teaching patients to call the manufacturer for replacements rather than waiting for a clinic visit.

Faculty Participants:

  • Jerry Rebo, PharmD, MBA, BCPS, BCCCP, DPLA, Novant Health (moderator)
  • Holly Canupp, PharmD, BCACP, CPP, CDE, Duke University Hospital
  • Megan Clarke, CPP, Novant Health
  • Mackie King, PharmD, MBA, BCPS, AAHIVP, CPP, Novant Health
  • Hillary Lockemer, MD, FAAP, WakeMed
  • Christina Sherrill, PharmD, FCCP, BCACP, BC-ADM, University of North Carolina
  • Rebecca Vitale, MD, MPH, University of North Carolina at Chapel Hill
  • Emelia Zhu, MPH, RD, LDN, CDCES, Duke Primary Care

Alarm settings are another lever. Faculty described devoting entire visits to adjusting alerts, and some endorsed placing sensors off label when arm sites keep failing. For example, Duke revised its CGM education to tell patients that even when care teams can see their data, no one will call after a low or high reading.

The speakers said clinicians often do not know a patient wears a device, especially when patients buy sensors over the counter. Novant Health created a generic CGM order with a device drop-down. “We have a generic CGM order, and then we have a smart list drop-down menu in there so you can choose whether it’s Stelo or Dexcom,” King said. The system also uses electronic health record flags for CGMs and pumps, plus an insulin-pump-from-home order that alerts a diabetes navigator on admission.

Integration efforts varied. WakeMed expects to go live with Tidepool soon; after an in-house build approximately 10 years ago produced an unreadable scatter plot. Faculty at WakeMed and Duke said third-party security reviews can take months to years. At Duke, only about 200 of the thousands of patients using CGMs are enrolled in the digital health platform Validic, which requires a 3-step setup.

“You’ve got to keep it simple for the patients. No matter that it looks like for the providers, if the patients don’t enroll, the providers are not going to see it,” Zhu said. UNC, too, has begun an integration project, but no data have flowed yet.

Will the HEDIS CGM Measure Reflect Quality?

Healthcare Effectiveness Data and Information set (HEDIS) measurement year 2027 adds a CGM utilization measure for adults aged 18 to 75 years with diabetes on insulin. Faculty questioned how it will be tracked, since diagnosis codes and medication lists depend on DME documentation. WakeMed automated other HEDIS reporting in Epic and said a similar build would be needed to avoid manual chart review.

Faculty said payer rules, which clinicians can’t control, often determine how consistently patients use CGMs. They cited 3 examples: some insurers have gone back to dispensing 1 month of sensors at a time, which can leave patients not spared when a sensor fails; pharmacies sometimes dispense fewer sensors than prescribed; and plans may deny reauthorization when a patient’s hemoglobin A1C has not dropped.

Research presented during the Roundtable cited a meta-analysis that found the odds of CGM use were 53% lower for Black patients and 41% lower for Hispanic patients than for non-Hispanic White patients.1 Faculty noted that apps are not always available in Spanish, that some patients need help creating an email address to open an account, and that a $40 to $50 co-pay for a CGM review can deter visits. One faculty member cited Duke Research Findings that White patients more often ask about diabetes technology, while Black and Hispanic patients more often wait for clinicians to raise the issue.

What Will Faculty Take Back to Their Health Systems?

Takeaways centered on visibility and measurement. “I go to figure out what our HEDIS plan is, because I don’t think I’ve heard much about it,” King said. Another faculty member called the generic CGM order a quick win for identifying patients using diabetes technology, and others plan to offer CGM proactively to underserved patients.

In a survey distributed after the event, 7 of 8 participants rated their organization’s urgency around CGM across the care continuum as “moderate” or “very high,” yet 6 of 8 described their readiness to document the HEDIS measure as “slight” or “non.” The faculty also suggested borrowing ideas from other remote monitoring programs.

Megan Clarke, CPP, of Novant Health, said device documentation is weak across health care. “It doesn’t have to be comprehensive. It just has to start,” she said.

Reference

  1. Rego MLM, Barnett M, Siqueira Tavares de Melo MH, Rivadeneira A. US race/ethnic disparities in diabetes technologies: a systematic review and meta-analysis of 950 000 individuals. J Endocr Soc. 2026;10(8):bvag150. doi:10.1210/jendso/bvag150

Related to this article